All DRAGONLAB pipettes have been quality tested according to ISO8655-2:2002 with calibration certificate. The quality control involves gravimetric testing of each pipette with distilled water at 22ºC.
 |  |
Features for TopPette
- Lightweight, ergonomic, low force design
- Digital display clearly reads volume setting
- The pipettes cover volume range of 0.1μl to 10ml
- Easy to calibrate and maintain with tool supplied
- Design helps avoid repetitive strain injuries
- Calibrated in accordance with ISO8655. Each pipette supplied with individual test certificate
- The low part is available for autoclaving
Features for multi-channel TopPette
- 8 and 12 channel pipettes are available for standard 96-well plate
- Dispensing head rotates for optimum pipetting convenience
- Individual piston and tip cone assemblies allow easy repair and maintenance
- Compound material tip cone design allows visual seal verification
- Can be used with universal style pipette tips
 |
 |
Calibration Please visit our website for online calibration at www.dragon-lab.com. Through the online calibration software, users can perform simple, accurate and timely calibration with free cost, and avoid the calibration error due to non-professional operation. Â We will support and help you to achieve consistently excellent results. Â |
 |
Â
Single-channel Adjustable Volume Pipettes | |||||||||||
Volume Range | Increment | Test Volume | Maximum permissible systematic error (Inaccuracy) | Maximum permissible random error (Imprecision) | |||||||
% | μL | % | μL | ||||||||
0.1-2.5μL | 0.05μL | 2.5μL | 2.50% | 0.0625 | 2.00% | 0.05 | |||||
1.25μL | 3.00% | 0.0375 | 3.00% | 0.0375 | |||||||
0.25μL | 12.00% | 0.03 | 6.00% | 0.015 | |||||||
0.5-10μL | 0.1μL | 10μL | 1.00% | 0.1 | 0.80% | 0.08 | |||||
5μL | 1.50% | 0.075 | 1.50% | 0.075 | |||||||
1μL | 2.50% | 0.025 | 1.50% | 0.015 | |||||||
2-20μL | 0.5μL | 20μL | 0.90% | 0.18 | 0.40% | 0.08 | |||||
10μL | 1.20% | 0.12 | 1.00% | 0.1 | |||||||
2μL | 3.00% | 0.06 | 2.00% | 0.04 | |||||||
5-50μL | 0.5μL | 50μL | 0.60% | 0.3 | 0.30% | 0.15 | |||||
25μL | 0.90% | 0.225 | 0.60% | 0.15 | |||||||
5μL | 2.00% | 0.1 | 2.00% | 0.1 | |||||||
10-100μL | 1μL | 100μL | 0.80% | 0.8 | 0.15% | 0.15 | |||||
50μL | 1.00% | 0.5 | 0.40% | 0.2 | |||||||
10μL | 3.00% | 0.3 | 1.50% | 0.15 | |||||||
20-200μL | 1μL | 200μL | 0.60% | 1.2 | 0.15% | 0.3 | |||||
100μL | 0.80% | 0.8 | 0.30% | 0.3 | |||||||
20μL | 3.00% | 0.6 | 1.00% | 0.2 | |||||||
50-200μL | 1μL | 200μL | 0.60% | 1.2 | 0.15% | 0.3 | |||||
100μL | 0.80% | 0.8 | 0.30% | 0.3 | |||||||
50μL | 1.00% | 0.5 | 0.40% | 0.2 | |||||||
100-1000μL | 5μL | 1000μL | 0.60% | 6 | 0.20% | 2 | |||||
500μL | 0.70% | 3.5 | 0.25% | 1.25 | |||||||
100μL | 2.00% | 2 | 0.70% | 0.7 | |||||||
200-1000μL | 5μL | 1000μL | 0.60% | 6 | 0.20% | 2 | |||||
500μL | 0.70% | 3.5 | 0.25% | 1.25 | |||||||
200μL | 0.90% | 1.8 | 0.30% | 0.6 | |||||||
1000-5000μL | 50μL | 5000μL | 0.50% | 25 | 0.15% | 7.5 | |||||
2500μL | 0.60% | 15 | 0.30% | 7.5 | |||||||
1000μL | 0.70% | 7 | 0.30% | 3 | |||||||
2-10mL | 0.1mL | 10mL | 0.60% | 60 | 0.20% | 20 | |||||
5mL | 1.20% | 60 | 0.30% | 15 | |||||||
2mL | 3.00% | 60 | 0.60% | 12 | |||||||
8-channel Adjustable Volume Pipettes | |||||||||||
Volume Range | Increment | Test Volume | Maximum permissible systematic error (Inaccuracy) | Maximum permissible random error (Imprecision) | |||||||
% | μL | % | μL | ||||||||
0.5-10μL | 0.1μL | 10μL | 1.50% | 0.15 | 1.50% | 0.15 | |||||
5μL | 2.50% | 0.125 | 2.50% | 0.125 | |||||||
1μL | 4.00% | 0.04 | 4.00% | 0.04 | |||||||
5-50μL | 0.5μL | 50μL | 1.00% | 0.5 | 0.50% | 0.25 | |||||
25μL | 1.50% | 0.375 | 1.00% | 0.25 | |||||||
5μL | 3.00% | 0.15 | 2.00% | 0.1 | |||||||
50-300μL | 5μL | 300μL | 0.70% | 2.1 | 0.25% | 0.75 | |||||
150μL | 1.00% | 1.5 | 0.50% | 0.75 | |||||||
50μL | 1.50% | 0.75 | 0.80% | 0.4 | |||||||
12-channel Adjustable Volume Pipettes | |||||||||||
Volume Range | Increment | Test Volume | Maximum permissible systematic error (Inaccuracy) | Maximum permissible random error (Imprecision) | |||||||
% | μL | % | μL | ||||||||
0.5-10μL | 0.1μL | 10μL | 1.50% | 0.15 | 1.50% | 0.15 | |||||
5μL | 2.50% | 0.125 | 2.50% | 0.125 | |||||||
1μL | 4.00% | 0.04 | 4.00% | 0.04 | |||||||
5-50μL | 0.5μL | 50μL | 1.00% | 0.5 | 0.50% | 0.25 | |||||
25μL | 1.50% | 0.375 | 1.00% | 0.25 | |||||||
5μL | 3.00% | 0.15 | 2.00% | 0.1 | |||||||
50-300μL | 5μL | 300μL | 0.70% | 2.1 | 0.25% | 0.75 | |||||
150μL | 1.00% | 1.5 | 0.50% | 0.75 | |||||||
50μL | 1.50% | 0.75 | 0.80% | 0.4 | |||||||
Fixed Volume Pipettes | |||||||||||
Volume Range | Increment | Test Volume | Maximum permissible systematic error (Inaccuracy) | Maximum permissible random error (Imprecision) | |||||||
% | μL | % | μL | ||||||||
5μL | - | 5μL | 1.3% | 0.065 | 1.2% | 0.06 | |||||
10μL | - | 10μL | 0.8% | 0.08 | 0.8% | 0.08 | |||||
20μL | - | 20μL | 0.6% | 0.12 | 0.5% | 0.1 | |||||
25μL | - | 25μL | 0.5% | 0.125 | 0.3% | 0.075 | |||||
50μL | - | 50μL | 0.5% | 0.25 | 0.3% | 0.15 | |||||
100μL | - | 100μL | 0.5% | 0.5 | 0.3% | 0.3 | |||||
200μL | - | 200μL | 0.4% | 0.8 | 0.2% | 0.4 | |||||
250μL | -- | 250μL | 0.4% | 1.0 | 0.2% | 0.5 | |||||
500μL | - | 500μL | 0.3% | 1.5 | 0.2% | 1.0 | |||||
1000μL | - | 1000μL | 0.3% | 3.0 | 0.2% | 2.0 | |||||
2000μL | - | 2000μL | 0.3% | 6.0 | 0.15% | 3.0 | |||||
5000μL | - | 5000μL | 0.3% | 15 | 0.15% | 7.5 |
All DRAGONLAB pipettes have been quality tested according to ISO8655-2:2002 with calibration certificate. The quality control involves gravimetric testing of each pipette with distilled water at 22ºC.
 |  |
Features for TopPette
- Lightweight, ergonomic, low force design
- Digital display clearly reads volume setting
- The pipettes cover volume range of 0.1μl to 10ml
- Easy to calibrate and maintain with tool supplied
- Design helps avoid repetitive strain injuries
- Calibrated in accordance with ISO8655. Each pipette supplied with individual test certificate
- The low part is available for autoclaving
Features for multi-channel TopPette
- 8 and 12 channel pipettes are available for standard 96-well plate
- Dispensing head rotates for optimum pipetting convenience
- Individual piston and tip cone assemblies allow easy repair and maintenance
- Compound material tip cone design allows visual seal verification
- Can be used with universal style pipette tips
 |
 |
Calibration Please visit our website for online calibration at www.dragon-lab.com. Through the online calibration software, users can perform simple, accurate and timely calibration with free cost, and avoid the calibration error due to non-professional operation. Â We will support and help you to achieve consistently excellent results. Â |
 |
Â
Single-channel Adjustable Volume Pipettes | |||||||||||
Volume Range | Increment | Test Volume | Maximum permissible systematic error (Inaccuracy) | Maximum permissible random error (Imprecision) | |||||||
% | μL | % | μL | ||||||||
0.1-2.5μL | 0.05μL | 2.5μL | 2.50% | 0.0625 | 2.00% | 0.05 | |||||
1.25μL | 3.00% | 0.0375 | 3.00% | 0.0375 | |||||||
0.25μL | 12.00% | 0.03 | 6.00% | 0.015 | |||||||
0.5-10μL | 0.1μL | 10μL | 1.00% | 0.1 | 0.80% | 0.08 | |||||
5μL | 1.50% | 0.075 | 1.50% | 0.075 | |||||||
1μL | 2.50% | 0.025 | 1.50% | 0.015 | |||||||
2-20μL | 0.5μL | 20μL | 0.90% | 0.18 | 0.40% | 0.08 | |||||
10μL | 1.20% | 0.12 | 1.00% | 0.1 | |||||||
2μL | 3.00% | 0.06 | 2.00% | 0.04 | |||||||
5-50μL | 0.5μL | 50μL | 0.60% | 0.3 | 0.30% | 0.15 | |||||
25μL | 0.90% | 0.225 | 0.60% | 0.15 | |||||||
5μL | 2.00% | 0.1 | 2.00% | 0.1 | |||||||
10-100μL | 1μL | 100μL | 0.80% | 0.8 | 0.15% | 0.15 | |||||
50μL | 1.00% | 0.5 | 0.40% | 0.2 | |||||||
10μL | 3.00% | 0.3 | 1.50% | 0.15 | |||||||
20-200μL | 1μL | 200μL | 0.60% | 1.2 | 0.15% | 0.3 | |||||
100μL | 0.80% | 0.8 | 0.30% | 0.3 | |||||||
20μL | 3.00% | 0.6 | 1.00% | 0.2 | |||||||
50-200μL | 1μL | 200μL | 0.60% | 1.2 | 0.15% | 0.3 | |||||
100μL | 0.80% | 0.8 | 0.30% | 0.3 | |||||||
50μL | 1.00% | 0.5 | 0.40% | 0.2 | |||||||
100-1000μL | 5μL | 1000μL | 0.60% | 6 | 0.20% | 2 | |||||
500μL | 0.70% | 3.5 | 0.25% | 1.25 | |||||||
100μL | 2.00% | 2 | 0.70% | 0.7 | |||||||
200-1000μL | 5μL | 1000μL | 0.60% | 6 | 0.20% | 2 | |||||
500μL | 0.70% | 3.5 | 0.25% | 1.25 | |||||||
200μL | 0.90% | 1.8 | 0.30% | 0.6 | |||||||
1000-5000μL | 50μL | 5000μL | 0.50% | 25 | 0.15% | 7.5 | |||||
2500μL | 0.60% | 15 | 0.30% | 7.5 | |||||||
1000μL | 0.70% | 7 | 0.30% | 3 | |||||||
2-10mL | 0.1mL | 10mL | 0.60% | 60 | 0.20% | 20 | |||||
5mL | 1.20% | 60 | 0.30% | 15 | |||||||
2mL | 3.00% | 60 | 0.60% | 12 | |||||||
8-channel Adjustable Volume Pipettes | |||||||||||
Volume Range | Increment | Test Volume | Maximum permissible systematic error (Inaccuracy) | Maximum permissible random error (Imprecision) | |||||||
% | μL | % | μL | ||||||||
0.5-10μL | 0.1μL | 10μL | 1.50% | 0.15 | 1.50% | 0.15 | |||||
5μL | 2.50% | 0.125 | 2.50% | 0.125 | |||||||
1μL | 4.00% | 0.04 | 4.00% | 0.04 | |||||||
5-50μL | 0.5μL | 50μL | 1.00% | 0.5 | 0.50% | 0.25 | |||||
25μL | 1.50% | 0.375 | 1.00% | 0.25 | |||||||
5μL | 3.00% | 0.15 | 2.00% | 0.1 | |||||||
50-300μL | 5μL | 300μL | 0.70% | 2.1 | 0.25% | 0.75 | |||||
150μL | 1.00% | 1.5 | 0.50% | 0.75 | |||||||
50μL | 1.50% | 0.75 | 0.80% | 0.4 | |||||||
12-channel Adjustable Volume Pipettes | |||||||||||
Volume Range | Increment | Test Volume | Maximum permissible systematic error (Inaccuracy) | Maximum permissible random error (Imprecision) | |||||||
% | μL | % | μL | ||||||||
0.5-10μL | 0.1μL | 10μL | 1.50% | 0.15 | 1.50% | 0.15 | |||||
5μL | 2.50% | 0.125 | 2.50% | 0.125 | |||||||
1μL | 4.00% | 0.04 | 4.00% | 0.04 | |||||||
5-50μL | 0.5μL | 50μL | 1.00% | 0.5 | 0.50% | 0.25 | |||||
25μL | 1.50% | 0.375 | 1.00% | 0.25 | |||||||
5μL | 3.00% | 0.15 | 2.00% | 0.1 | |||||||
50-300μL | 5μL | 300μL | 0.70% | 2.1 | 0.25% | 0.75 | |||||
150μL | 1.00% | 1.5 | 0.50% | 0.75 | |||||||
50μL | 1.50% | 0.75 | 0.80% | 0.4 | |||||||
Fixed Volume Pipettes | |||||||||||
Volume Range | Increment | Test Volume | Maximum permissible systematic error (Inaccuracy) | Maximum permissible random error (Imprecision) | |||||||
% | μL | % | μL | ||||||||
5μL | - | 5μL | 1.3% | 0.065 | 1.2% | 0.06 | |||||
10μL | - | 10μL | 0.8% | 0.08 | 0.8% | 0.08 | |||||
20μL | - | 20μL | 0.6% | 0.12 | 0.5% | 0.1 | |||||
25μL | - | 25μL | 0.5% | 0.125 | 0.3% | 0.075 | |||||
50μL | - | 50μL | 0.5% | 0.25 | 0.3% | 0.15 | |||||
100μL | - | 100μL | 0.5% | 0.5 | 0.3% | 0.3 | |||||
200μL | - | 200μL | 0.4% | 0.8 | 0.2% | 0.4 | |||||
250μL | -- | 250μL | 0.4% | 1.0 | 0.2% | 0.5 | |||||
500μL | - | 500μL | 0.3% | 1.5 | 0.2% | 1.0 | |||||
1000μL | - | 1000μL | 0.3% | 3.0 | 0.2% | 2.0 | |||||
2000μL | - | 2000μL | 0.3% | 6.0 | 0.15% | 3.0 | |||||
5000μL | - | 5000μL | 0.3% | 15 | 0.15% | 7.5 |
Terry Towel Warp Knitting Machine
Terry Towel Warp Knitting Machine is a highly-speed warp knitting machine, which running speed could up to 1,300RPM. Thanks to advanced technology and carbon fiber material widely used, warp knitting terry towel machine becomes more stable and higher productive compared with other terry machines.
A-ZEN TS4-C terry towel warp knitting machines, which also be called KS4FBZ, is equipped with Germany Needles, Carbon-fiber Needle bed and bars, laser-stops device as well as other market-tested spare parts, because of which A-ZEN terry towel machines gain a market acceptance since last 4 years.
Piles of warp knitting terry could reach to 6mm while back side of terry could be 3-4mm. The weight of warp knitting terry usually from 200-400gsm. Microfiber Polyester, Polyamaid and cotton yarn are available in warp knitting terry machine.
Technical Data:
Working Width/Gauge: 186"/ E24;
Working Speed: 50-1300rpm (Depends on yarn and designs);
Pattern Drive System: Pattern Disc or EL Drive (Optional);
Yarn Let-off Device: Electronical Yarn Let-off System;
Fabric Take-up: Electronical Fabric Take-up System;
Batching Device: Electronical Batching Device;
Laser Stops Detector;
Individual Terry Pile Brushing Device;
Online Service Supported.
Details please check machine leaflet.
Terry Towel Warp knitting machine,Terry machine,Microfiber towel machine
CHANGHZOU A-ZEN TEXTILE TECHNOLOGY CO.,LTD , https://www.barmachinery.com