Specifications:Â L-YQX-I/II
Â
ApplicationRange:
This type of product is in the bacterial culture under anaerobic conditions and operating. This device can nurture the growth of anaerobic organisms most difficult. Anaerobic organisms can avoid the risk of death that anaerobic organisms are exposed to oxygen.
Structural Characteristics:
The equipment is composed of the incubation chamber, operating chamber, sampling chamber, pneumatics system, bottle rack, melting wax sterilize and etc.
MainFeatures:
1. Microcomputer intelligent temperature controlling and overheating protection system.
2. UV disinfection light to avoid pollution.
3. Gas flow adjusted by pneumatics system.
4. Stainless steel operation room chamber. Thick, transparent and impact resistant glass window. Operations should be with gloves.
5. Special vaccination sticks sterilizer, cuvette rack and oxygen removing catalyst converter inside.
YQX-IIFeatures:
1.Big LCD screen controller.
2.Touch switch for gas path control.
Technical Parameter Table:
Â
Â
Model | YQX-I/II/Â T |
Time for creating anaerobic state in sample chamber | <5min |
Time for creating anaerobic state in operation chamber | <1hour |
Time for maintaining anaerobic circumstances | in the case of the operating room to stop additional trace gas mixture,>12 hours |
Range of temperature-control in incubation chamber | RT+3ºC~60ºC |
Temperature fluctuation in incubation chamber | ±0.3ºC |
Temperature balance in incubation chamber | ±1ºC |
Power Rate | 220V,50HZ/600W |
Net/Gross weight(kg) | 240/320 |
Internal Dimension of Incubation Chamber(cm) | 30×19×29 |
Dimension of Operation Chamber(cm) | 80×65×65 |
Overall Dimension(cm) | 126×73×138 |
Package Size(cm) | 139×92×156 |
Product Name: L-YQX-I/II Anaerobic incubator
Specifications:Â L-YQX-I/II
Â
ApplicationRange:
This type of product is in the bacterial culture under anaerobic conditions and operating. This device can nurture the growth of anaerobic organisms most difficult. Anaerobic organisms can avoid the risk of death that anaerobic organisms are exposed to oxygen.
Structural Characteristics:
The equipment is composed of the incubation chamber, operating chamber, sampling chamber, pneumatics system, bottle rack, melting wax sterilize and etc.
MainFeatures:
1. Microcomputer intelligent temperature controlling and overheating protection system.
2. UV disinfection light to avoid pollution.
3. Gas flow adjusted by pneumatics system.
4. Stainless steel operation room chamber. Thick, transparent and impact resistant glass window. Operations should be with gloves.
5. Special vaccination sticks sterilizer, cuvette rack and oxygen removing catalyst converter inside.
YQX-IIFeatures:
1.Big LCD screen controller.
2.Touch switch for gas path control.
Technical Parameter Table:
Â
Â
Model | YQX-I/II/Â T |
Time for creating anaerobic state in sample chamber | <5min |
Time for creating anaerobic state in operation chamber | <1hour |
Time for maintaining anaerobic circumstances | in the case of the operating room to stop additional trace gas mixture,>12 hours |
Range of temperature-control in incubation chamber | RT+3ºC~60ºC |
Temperature fluctuation in incubation chamber | ±0.3ºC |
Temperature balance in incubation chamber | ±1ºC |
Power Rate | 220V,50HZ/600W |
Net/Gross weight(kg) | 240/320 |
Internal Dimension of Incubation Chamber(cm) | 30×19×29 |
Dimension of Operation Chamber(cm) | 80×65×65 |
Overall Dimension(cm) | 126×73×138 |
Package Size(cm) | 139×92×156 |
â—†TC-01 Temperature Control Heatsink | ||||||||||||||||
|
||||||||||||||||
Specifications |
||||||||||||||||
|
||||||||||||||||
â—† TC-02 Normal Heatsink | ||||||||||||||||
|
||||||||||||||||
Specifications |
||||||||||||||||
|
||||||||||||||||
â—†TC-03 Heatsink | ||||||||||||||||
|
||||||||||||||||
Specifications | ||||||||||||||||
|
Heatsink
Laser Heatsink,Laser Heat Sink,Laser Diode Heatsink, Laser Module Heatsink
Changchun New Industries Optoelectronics Technology Co., Ltd. , https://www.cnioptics.com