End Suction Diesel Engine Automatic Fire Fighting Water Pump

Model NO.: XBC
Power: Diesel Engine
Start Up: Electric Pump
Type: Blade Pump
Application: Clarified Water Pump
Industry: Fire Fight
Media: Clear Water
Performance: Automatic Pump
Theory: Centrifugal Pump
Water Pump: Fire Fighting Pump
Diesel Engine Pump: Diesel Engine Pump
Fire Fighting: Diesel Water Pump
Pump: Fire Pump
Fire Fighting Equipment: Diesel Pump
Trademark: Borra
Transport Package: Wood Case
Specification: ISO
Origin: Wenzhou
HS Code: 8413810090
Model NO.: XBC
Power: Diesel Engine
Start Up: Electric Pump
Type: Blade Pump
Application: Clarified Water Pump
Industry: Fire Fight
Media: Clear Water
Performance: Automatic Pump
Theory: Centrifugal Pump
Water Pump: Fire Fighting Pump
Diesel Engine Pump: Diesel Engine Pump
Fire Fighting: Diesel Water Pump
Pump: Fire Pump
Fire Fighting Equipment: Diesel Pump
Trademark: Borra
Transport Package: Wood Case
Specification: ISO
Origin: Wenzhou
HS Code: 8413810090
Diesel Engine Automatic Fire Fight Water Pum

As per head, flow and media, the flow range: 10-870L/s, pressure range: 0.15-6MPa, diesel engine rotation speed range: 1500-2900rpm. 
Used for emergency water supply in high buildings, taper water, steel factories, wine plants, chemical factories, hotels. Automatic, full functions, good structure, easy to install and use.
as per conditions: 1-stage 1-priming centrifugal pump, high-pressure multi-stage pump, 2-priming pump.


Run conditions:
1. Altitude: ≤2500m
2. Ambient temperature: -25~55ºC
3. Ambient relative humidity: 9~95%
4. Anti-earthquake degree: degree 7
5. Flow range: 50-700(L/S)
6. Head range: 32-600m
7. Power: 18-1100KW
8. Wet part materials: cast iron, graphite cast iron, stainless steel, cast copper.


Automatic control cabinet:
1. Manual and automatic controls, button by hand to start, run stop, failure safeguard, program control and process control.
2. Automatic monitor on engine speed changes in start, idle, speed-up, full-speed, high-speed & low-speed emergency stop. The status indication by monitor and indicator lights: idle, start, oil supply, self-start, rotation speed indication, idle delay, normal run, cooled stop, emergency stop.
 End Suction Diesel Engine Automatic Fire Fighting Water PumpEnd Suction Diesel Engine Automatic Fire Fighting Water Pump
End Suction Diesel Engine Automatic Fire Fighting Water Pump

Technical parameters:
Type Flow Q
(L/s)
Outlet pressure (MPa) Rotation n
(r/min)
Power P (Kw) Efficiency η (%)
XBC3.0/5-50(65) 5 0.30 2900 4 63
XBC3.2/5-50(65) 0.32
XBC3.4/5-50(65) 0.34
XBC4.6/5-50(65) 5 0.46 2900 7.5 58
XBC4.8/5-50(65) 0.48
XBC5.0/5-50(65) 0.50
XBC7.6/5-50(65) 5 0.76 2900 15 50
XBC7.8/5-50(65) 0.78
XBC8.0/5-50(65) 0.80
XBC11/5-50(65) 5 1.10 2900 30 40
XBC12/5-50(65) 1.20
XBC12.5/5-50(65) 1.25
XBC3.0/10-65(80) 10 0.30 2900 7.5 71
XBC3.2/10-65(80) 0.32
XBC3.4/10-65(80) 0.34
XBC4.6/10-65(80) 10 0.46 2900 15 67
XBC4.8/10-65(80) 0.48
XBC5.0/10-65(80) 0.50
XBC7.6/10-65(80) 10 0.76 2900 22 59
XBC7.8/10-65(80) 0.78
XBC8.0/10-65(80) 0.80
XBC11/10-65(80) 10 1.10 2900 37 54
XBC12/10-65(80) 1.20
XBC12.5/10-65(80) 1.25
XBC3.0/25-80(100) 25 0.30 2900 15 76
XBC3.2/25-80(100) 0.32
XBC3.4/25-80(100) 0.34
XBC4.6/25-80(100) 25 0.46 2900 22 74
XBC4.8/25-80(100) 0.48
XBC5.0/25-80(100) 0.50
XBC7.6/25-80(100) 25 0.76 2900 37 69
XBC7.8/25-80(100) 0.78
XBC8.0/25-80(100) 0.80
XBC11/25-80(100) 25 1.10 2900 75 69
XBC12/25-80(100) 1.20
XBC12.5/25-80(100) 1.25
XBC13/25-80(100) 25 1.30 2900 90 57
XBC14/25-80(100) 1.40
XBC15/25-80(100) 1.50
XBC3.0/45-125 45 0.30 2900 22 73
XBC3.2/45-125 0.32
XBC3.4/45-125 0.34
XBC4.6/45-125) 45 0.46 2900 37 77
XBC4.8/45-125 0.48
XBC5.0/45-125 0.50
XBC7.6/45-125 45 0.76 2900 55 80
XBC7.8/45-125 0.78
XBC8.0/45-125 0.80
XBC11/45-125 45 1.10 2900 90 70
XBC12/45-125 1.20
XBC12.5/45-125 1.25
XBC2.8/55-150 55 0.28 1450 30 78
XBC3.0/55-150 0.30
XBC3.2/55-150 0.32
XBC4.6/55-150 55 0.46 1450 45 75
XBC4.8/55-150 0.48
XBC5.0/55-150 0.50
XBC7.6/55-150 55 0.76 2900 75 76
XBC7.8/55-150 0.78
XBC8.0/55-150 0.80
XBC11/55-150 55 1.10 2900 110 73
XBC12/55-150 1.20
XBC12.5/55-150 1.25
XBC13/55-150 45 1.30 2900 110 80
XBC14/55-150 1.40
XBC15/55-150 1.50
XBC4.6/100-200 100 0.46 1450 75 81
XBC4.8/100-200 0.48
XBC5.0/100-200 0.50
XBC3.0/150-250 150 0.30 1450 75 80
XBC3.2/150-250 0.32
XBC3.4/150-250 0.34
XBC4.6/140-250 140 0.46 1450 90 72
XBC4.8/140-250 0.48
XBC5.0/140-250 0.50
XBC2.4/200-300 200 0.24 970 75 81
XBC2.6/200-300 0.26
XBC2.8/200-300 0.28
XBC2.8/200-300 200 0.28 1450 90 84
XBC3.0/200-300 0.30
XBC3.2/200-300 0.32
XBC4.0/200-300 200 0.40 970 132 84
XBC4.2/200-300 0.42
XBC4.4/200-300 0.44
XBC4.6/160-300 160 0.46 1450 110 78
XBC4.8/160-300 0.48
XBC5.0/160-300 0.50
XBC4.6/200-350 200 0.46 1450 160 83
XBC4.8/200-350 0.48
XBC5.0/200-350 0.50
XBC2.8/300-400 300 0.28 1450 132 76
XBC3.0/300-400 0.30
XBC3.2/300-400 0.32
XBC2.8/330-500 330 0.28 1450 160 78
XBC3.0/330-500 0.30
XBC3.2/330-500 0.32

End Suction Diesel Engine Automatic Fire Fighting Water PumpEnd Suction Diesel Engine Automatic Fire Fighting Water PumpEnd Suction Diesel Engine Automatic Fire Fighting Water Pump




  Diesel Engine Automatic Fire Fight Water Pum

As per head, flow and media, the flow range: 10-870L/s, pressure range: 0.15-6MPa, diesel engine rotation speed range: 1500-2900rpm. 
Used for emergency water supply in high buildings, taper water, steel factories, wine plants, chemical factories, hotels. Automatic, full functions, good structure, easy to install and use.
as per conditions: 1-stage 1-priming centrifugal pump, high-pressure multi-stage pump, 2-priming pump.


Run conditions:
1. Altitude: ≤2500m
2. Ambient temperature: -25~55ºC
3. Ambient relative humidity: 9~95%
4. Anti-earthquake degree: degree 7
5. Flow range: 50-700(L/S)
6. Head range: 32-600m
7. Power: 18-1100KW
8. Wet part materials: cast iron, graphite cast iron, stainless steel, cast copper.


Automatic control cabinet:
1. Manual and automatic controls, button by hand to start, run stop, failure safeguard, program control and process control.
2. Automatic monitor on engine speed changes in start, idle, speed-up, full-speed, high-speed & low-speed emergency stop. The status indication by monitor and indicator lights: idle, start, oil supply, self-start, rotation speed indication, idle delay, normal run, cooled stop, emergency stop.
 End Suction Diesel Engine Automatic Fire Fighting Water PumpEnd Suction Diesel Engine Automatic Fire Fighting Water Pump
End Suction Diesel Engine Automatic Fire Fighting Water Pump

Technical parameters:
Type Flow Q
(L/s)
Outlet pressure (MPa) Rotation n
(r/min)
Power P (Kw) Efficiency η (%)
XBC3.0/5-50(65) 5 0.30 2900 4 63
XBC3.2/5-50(65) 0.32
XBC3.4/5-50(65) 0.34
XBC4.6/5-50(65) 5 0.46 2900 7.5 58
XBC4.8/5-50(65) 0.48
XBC5.0/5-50(65) 0.50
XBC7.6/5-50(65) 5 0.76 2900 15 50
XBC7.8/5-50(65) 0.78
XBC8.0/5-50(65) 0.80
XBC11/5-50(65) 5 1.10 2900 30 40
XBC12/5-50(65) 1.20
XBC12.5/5-50(65) 1.25
XBC3.0/10-65(80) 10 0.30 2900 7.5 71
XBC3.2/10-65(80) 0.32
XBC3.4/10-65(80) 0.34
XBC4.6/10-65(80) 10 0.46 2900 15 67
XBC4.8/10-65(80) 0.48
XBC5.0/10-65(80) 0.50
XBC7.6/10-65(80) 10 0.76 2900 22 59
XBC7.8/10-65(80) 0.78
XBC8.0/10-65(80) 0.80
XBC11/10-65(80) 10 1.10 2900 37 54
XBC12/10-65(80) 1.20
XBC12.5/10-65(80) 1.25
XBC3.0/25-80(100) 25 0.30 2900 15 76
XBC3.2/25-80(100) 0.32
XBC3.4/25-80(100) 0.34
XBC4.6/25-80(100) 25 0.46 2900 22 74
XBC4.8/25-80(100) 0.48
XBC5.0/25-80(100) 0.50
XBC7.6/25-80(100) 25 0.76 2900 37 69
XBC7.8/25-80(100) 0.78
XBC8.0/25-80(100) 0.80
XBC11/25-80(100) 25 1.10 2900 75 69
XBC12/25-80(100) 1.20
XBC12.5/25-80(100) 1.25
XBC13/25-80(100) 25 1.30 2900 90 57
XBC14/25-80(100) 1.40
XBC15/25-80(100) 1.50
XBC3.0/45-125 45 0.30 2900 22 73
XBC3.2/45-125 0.32
XBC3.4/45-125 0.34
XBC4.6/45-125) 45 0.46 2900 37 77
XBC4.8/45-125 0.48
XBC5.0/45-125 0.50
XBC7.6/45-125 45 0.76 2900 55 80
XBC7.8/45-125 0.78
XBC8.0/45-125 0.80
XBC11/45-125 45 1.10 2900 90 70
XBC12/45-125 1.20
XBC12.5/45-125 1.25
XBC2.8/55-150 55 0.28 1450 30 78
XBC3.0/55-150 0.30
XBC3.2/55-150 0.32
XBC4.6/55-150 55 0.46 1450 45 75
XBC4.8/55-150 0.48
XBC5.0/55-150 0.50
XBC7.6/55-150 55 0.76 2900 75 76
XBC7.8/55-150 0.78
XBC8.0/55-150 0.80
XBC11/55-150 55 1.10 2900 110 73
XBC12/55-150 1.20
XBC12.5/55-150 1.25
XBC13/55-150 45 1.30 2900 110 80
XBC14/55-150 1.40
XBC15/55-150 1.50
XBC4.6/100-200 100 0.46 1450 75 81
XBC4.8/100-200 0.48
XBC5.0/100-200 0.50
XBC3.0/150-250 150 0.30 1450 75 80
XBC3.2/150-250 0.32
XBC3.4/150-250 0.34
XBC4.6/140-250 140 0.46 1450 90 72
XBC4.8/140-250 0.48
XBC5.0/140-250 0.50
XBC2.4/200-300 200 0.24 970 75 81
XBC2.6/200-300 0.26
XBC2.8/200-300 0.28
XBC2.8/200-300 200 0.28 1450 90 84
XBC3.0/200-300 0.30
XBC3.2/200-300 0.32
XBC4.0/200-300 200 0.40 970 132 84
XBC4.2/200-300 0.42
XBC4.4/200-300 0.44
XBC4.6/160-300 160 0.46 1450 110 78
XBC4.8/160-300 0.48
XBC5.0/160-300 0.50
XBC4.6/200-350 200 0.46 1450 160 83
XBC4.8/200-350 0.48
XBC5.0/200-350 0.50
XBC2.8/300-400 300 0.28 1450 132 76
XBC3.0/300-400 0.30
XBC3.2/300-400 0.32
XBC2.8/330-500 330 0.28 1450 160 78
XBC3.0/330-500 0.30
XBC3.2/330-500 0.32

End Suction Diesel Engine Automatic Fire Fighting Water PumpEnd Suction Diesel Engine Automatic Fire Fighting Water PumpEnd Suction Diesel Engine Automatic Fire Fighting Water Pump




 

    Industrial water chillers/industrial chiller and cooling towers are the most important equipment during plastic molding and processing industry. The air-cooled water chillers and water-cooled water chiillers/Water Chiller are mainly used to reduce the temperature of plastic mould, the machine can reduce the molding cycle time and get a more smooth and perfect plastic products. The cooling towers are always used to cool the oil and hydraulic parts of plastic injection molding achine. Also, the cooling towers are necessary equipment to cooperate with water-cooled chillers, to cool the condenser of chillers.Except them,we also supply Industrial Water Cooling Machine,Water Chilling Machine,industrial water chilling unit.

Water Chiller & Cooling Tower

Industrial Water Chiller,Water Cooling Tower,Water Chiller Machine,Industrial Water Cooling Tower,Water Chilling Machine,Industrial Water Cooling Machine,Water Chiller

Ningbo Rainbow Plastics Machinery Co., Ltd. , https://www.injection-machine.com

Posted on