Model NO.: YL-SF-2000
Flow Rate: 95-155 Tph
Form: by-Pass
Average Remove Rate: 92%--96%
Inlet Pressure: 0.2-0.6MPa
Filter Media: Quartz Sand/Activated/Carboniron & Manganese
Backwash: Automatic
Thickness: 6mm
Inlet-Outlet Diameter: 6 Inch
Trademark: YLD
Transport Package: Plywood Case Into Container
Specification: CE, SGS
Origin: Jiangyin, Jiangsu
HS Code: 842121999
Model NO.: YL-SF-2000
Flow Rate: 95-155 Tph
Form: by-Pass
Average Remove Rate: 92%--96%
Inlet Pressure: 0.2-0.6MPa
Filter Media: Quartz Sand/Activated/Carboniron & Manganese
Backwash: Automatic
Thickness: 6mm
Inlet-Outlet Diameter: 6 Inch
Trademark: YLD
Transport Package: Plywood Case Into Container
Specification: CE, SGS
Origin: Jiangyin, Jiangsu
HS Code: 842121999
River Water Mechaical Recirculating Sand Filter (YL-SF-2000)
Product Introduction
By-pass filter for chilled water as a by-pass filtering equipment of closed industrial circulating water is used to filter the circulating chilled water and its control modes consist of manual backwash and automatic backwash. The system is generally backwashed once every three to seven days in the circulating process, effectively improving the quality of chilled water and ensuring excellent and stable water quality after intervention to long-term running. The device has small water consumption and is widely used in the cleaning of all types of industrial and commercial chilled water circulation system as well as refrigerant water and heat medium water systems of central air conditioning, improving the stability of equipment operation. Users may weld and conned in parallel the by-pass filters in main return pipes depending on the conditions of circulation system and the pipe diameter should be determined based on the retaining water yield of parallel circulating water. The sewage water is then discharged into the sewerage network.
The characteristics of the filtration system
1. Manual or automatic control is available;
2. Water distributor is simple, uniform and reliable;
3. Finished water collector has high strength and long service life;
4. Easy to install. Only connect the inlet and outlet to the waste pipe when installing;
5. Less water consumption in backwash: a homogeneous filter is used, so that backwash cycle is extended and the total backwash water volume is greatly reduced;
6. High backwash efficiency: an advanced water collector is used, ensuring efficient backwash effect.
FAQ:
01. how small a solid needs to be removed,
02. how dirty the water is,
03. how the water will be used once it is filtered,
04. and the source of backwash water needed to clean the filters.
Specifications:
model |
Filter diameter |
Height |
inlet-outlet |
Filtration area |
capacity |
mm |
mm |
mm |
m² |
m³/hour |
|
YL-SF-500 |
500 |
816 |
40 |
0.2 |
6~10 |
YL-SF-600 |
600 |
874 |
40 |
0.28 |
8~14 |
YL-SF-700 |
700 |
900 |
40 |
0.38 |
12~19 |
YL-SF-800 |
800 |
960 |
DN50 |
0.50 |
15-25 |
YL-SF-1000 |
1000 |
1200 |
DN50 |
0.79 |
23-39 |
YL-SF-1200 |
1200 |
1400 |
DN80 |
1.13 |
33-55 |
YL-SF-1400 |
1400 |
1600 |
DN100 |
1.54 |
45-75 |
YL-SF-1600 |
1600 |
1800 |
DN100 |
2.01 |
60-100 |
YL-SF-1800 |
1800 |
1950 |
DN150 |
2.54 |
75-125 |
YL-SF-2000 |
2000 |
2150 |
DN150 |
3.14 |
95-155 |
YL-SF-2200 |
2200 |
2250 |
DN150 |
3.80 |
115-190 |
YL-SF-2400 |
2400 |
2100 |
DN150 |
4.52 |
130-210 |
YL-SF-2600 |
2600 |
2400 |
DN150 |
5.30 |
145-225 |
YL-SF-2800 |
2800 |
2500 |
DN200 |
6.15 |
155-240 |
YL-SF-3000 |
3000 |
2600 |
DN200 |
7.00 |
170-255 |
YL-SF-3200 |
3200 |
2800 |
DN250 |
8.15 |
270-320 |
Â
River Water Mechaical Recirculating Sand Filter (YL-SF-2000)
Product Introduction
By-pass filter for chilled water as a by-pass filtering equipment of closed industrial circulating water is used to filter the circulating chilled water and its control modes consist of manual backwash and automatic backwash. The system is generally backwashed once every three to seven days in the circulating process, effectively improving the quality of chilled water and ensuring excellent and stable water quality after intervention to long-term running. The device has small water consumption and is widely used in the cleaning of all types of industrial and commercial chilled water circulation system as well as refrigerant water and heat medium water systems of central air conditioning, improving the stability of equipment operation. Users may weld and conned in parallel the by-pass filters in main return pipes depending on the conditions of circulation system and the pipe diameter should be determined based on the retaining water yield of parallel circulating water. The sewage water is then discharged into the sewerage network.
The characteristics of the filtration system
1. Manual or automatic control is available;
2. Water distributor is simple, uniform and reliable;
3. Finished water collector has high strength and long service life;
4. Easy to install. Only connect the inlet and outlet to the waste pipe when installing;
5. Less water consumption in backwash: a homogeneous filter is used, so that backwash cycle is extended and the total backwash water volume is greatly reduced;
6. High backwash efficiency: an advanced water collector is used, ensuring efficient backwash effect.
FAQ:
01. how small a solid needs to be removed,
02. how dirty the water is,
03. how the water will be used once it is filtered,
04. and the source of backwash water needed to clean the filters.
Specifications:
model |
Filter diameter |
Height |
inlet-outlet |
Filtration area |
capacity |
mm |
mm |
mm |
m² |
m³/hour |
|
YL-SF-500 |
500 |
816 |
40 |
0.2 |
6~10 |
YL-SF-600 |
600 |
874 |
40 |
0.28 |
8~14 |
YL-SF-700 |
700 |
900 |
40 |
0.38 |
12~19 |
YL-SF-800 |
800 |
960 |
DN50 |
0.50 |
15-25 |
YL-SF-1000 |
1000 |
1200 |
DN50 |
0.79 |
23-39 |
YL-SF-1200 |
1200 |
1400 |
DN80 |
1.13 |
33-55 |
YL-SF-1400 |
1400 |
1600 |
DN100 |
1.54 |
45-75 |
YL-SF-1600 |
1600 |
1800 |
DN100 |
2.01 |
60-100 |
YL-SF-1800 |
1800 |
1950 |
DN150 |
2.54 |
75-125 |
YL-SF-2000 |
2000 |
2150 |
DN150 |
3.14 |
95-155 |
YL-SF-2200 |
2200 |
2250 |
DN150 |
3.80 |
115-190 |
YL-SF-2400 |
2400 |
2100 |
DN150 |
4.52 |
130-210 |
YL-SF-2600 |
2600 |
2400 |
DN150 |
5.30 |
145-225 |
YL-SF-2800 |
2800 |
2500 |
DN200 |
6.15 |
155-240 |
YL-SF-3000 |
3000 |
2600 |
DN200 |
7.00 |
170-255 |
YL-SF-3200 |
3200 |
2800 |
DN250 |
8.15 |
270-320 |
Â
High Speed Twin Screw Extruder
Clamshell Barrel Extruder,Closed Barrel Twin-Screw Extruder,Wide Application Twin-Screw Extruder,Pshj 35 Twin-Screw Extruder
JIANGSU XINDA TECH LIMITED , https://www.xindaextruder.com