ISO 6848 | Type | Size | Part Number |
Color Chart RED AWS A5.12 EWTh-2 ISO 6848 WT20 |
2% Thoriated tungsten:Best stability at medium currents,good arc starts,medium tendency to spit, medium erosion rate |
.020x7''(0.5mmx175mm .040x7''(1.0mmx175mm) 1/16x7''(1.6mmx175mm) 3/32x7''(2.4mmx175mm) 1/8x7''(3.2mmx175mm) 5/32x7''(4.0mmx175mm) |
T0207GT2 T0407GT2 T1167GT2 T3327GT2 T187GT2 T5327GT2 |
WHITE AWS A5.12 none ISO 6848 WZ8 |
.8% Zirconiated tungsten:Balls well,handles higher current with less spitting,best DC arc starts and stability than pure tungsten | .020x7''(0.5mmx175mm) .040x7''(1.0mmx175mm) 1/16x7''(1.6mmx175mm) 3/32x7''(2.4mmx175mm) 1/8x7''(3.2mmx175mm) 5/32x7''(4.0mmx175mm) .020x7''(0.5mmx175mm) |
T0207GZ T0407GZ T1167GZ T3327GZ T187GZ T5327GZ T0207GZ |
GOLD AWS A5.12EWLa-1.5 ISO 6848 WL15 |
1.5%Lanthanated tungsten:Lowest erosion rate,wide current range,no spitting,best DC arc starts and stability | .040x7''(1.0mmx175mm) 1/16x7''(1.6mmx175mm) 3/32x7''(2.4mmx175mm) 1/8x7''(3.2mmx175mm) 5/32x7''(4.0mmx175mm) .020x7''(0.5mmx175mm) |
T0407GL T1167GL T3327GL T187GL T5327GL T0207GC2 |
GRAY ISO 6848 WC20 Orange for AWS A5.12 EWCe-2 |
2% Ceriated tungsten:Low erosion rate,wide current range,AC or DC,no spitting,consistent arc starts,good stability | .040x7''(1.0mmx175mm) 1/16x7''(1.6mmx175mm) 3/32x7''(2.4mmx175mm) 1/8x7''(3.2mmx175mm) 5/32x7''(4.0mmx175mm) .020x7''(0.5mmx175mm) |
T0407GC2 T1167GC2 T3327GC2 T187GC2 T5327GC2 T0207G |
GREEN AWS A5.12EWP ISO 6848 WP |
Pure tungsten:Balls easily,low cost,tends to spit at higher currents,used for non-critical welds only | .040x7''(1.0mmx175mm) 1/16x7''(1.6mmx175mm) 3/32x7''(2.4mmx175mm) 1/8x7''(3.2mmx175mm) 5/32x7''(4.0mmx175mm) |
T0407G T1167G T3327G T187G T5327G |
Refrigerated dryer with a cooling condensation working principle, mainly consists of the heat exchange system, cooling system and electrical control system. First, the compressed air into the pre-cooler for air - gas or air - water heat exchange, removing a portion of heat, then into the hot and cold air exchanger, makes heat changes with the cooled air which has come out from the evaporator and cooled to a pressure dew point. Then the compressed air temperature is further reduced. After the compressed air into the evaporator, the heat exchange with the refrigerant, the compressed air temperature to 0-8 °C, moisture in the air at this temperature for precipitation, separated by the gas-water separator, after automatic drainage discharge. The low-temperature and dry air enters cold air exchanger for heat exchange, the output temperature.
Compressed Air Dryer,Air Compressor Dryer,Refrigerated Air Dryer,Air Dryer For Air Compressor,Air Dryer
Quzhou Zhongdu Machinery Technology Co., Ltd. , http://www.moderatemachine.com