Cone crusher technical operation procedures

16.1 Operating conditions:

16.1.1 It is necessary to have perfect safety protection, control interlocking oil pressure adjusting device, and equipped with all necessary, sensitive and reliable metering device.

16.1.2 The lubrication system is reliable and the oil passage is unobstructed.

16.1.3 The cone crusher must be equipped with a water seal dustproof device.

16.1.4 The crushing gap of the cone crusher shall not be less than the specified value and shall be measured periodically.

16.1.5 The amount of spring compression must be the same, meet the specified value, and should not be adjusted at will. If it is broken, it must be replaced in time.

16.1.6 The rolling wall and the broken wall are absolutely forbidden to contact in any case.

16.1.7 cone crusher mine mouth and to be fitted with the dust discharging opening means and the electromagnet is provided on the hand-picked and enhance several processes.

16.2 Inspection, driving sequence and precautions before driving:

16.2.1 Inspection before driving:

Check parts

Check content

Lubrication system

1. Check if the oil in the tank reaches the oil mark

2. Check if the switch position of the valve of the oil pipe is appropriate

3. Check if the oil pipeline connection is firm and reliable.

4. Start the oil pump and test whether there is any fault (refer to the oil pump driven by the separate power)

Dustproof system

Whether the dustproof water is unobstructed

Transmission section

1. Bearings, screws, pulleys, keys are loose

2. If it is a belt drive, check if the belt tightness is suitable.

3. Is the coupling screw complete and reliable?

Various parts of the body

1. Are the screws in each part loose?

2. Is the broken wall pressure cap loose?

3. Whether there is ore in the crushing chamber

Spring part

1. Is there any debris in the spring?

2. Does the amount of compression meet the requirements?

3. Is the spring and spring screw broken?

Electrical device

section

1. Check whether the operation buttons such as motor, starter device and electronic control system are in normal position.

2. Check whether the screws of each part of the motor are loose, the grounding wire is reliable, and there is no broken ore or debris in the motor.

3. Is the voltage normal and the ammeter pointer is at zero?

4. When the motor is stopped for more than three days, the insulation resistance should be measured at the start, and then drive when the requirements are met.

Hydraulic part

1. Oil pressure must be kept above 80kg/cm 2

2. The accumulator must maintain a nitrogen pressure of 75-80 kg/cm 2 (supplemented when insufficient)

16.2.2 Inspection must be carried out in accordance with the inspection items before operation.

16.2.3 Driving in the following order:

16.2.3.1 Start the lubricating oil pump and confirm that all parts of the machine are fully lubricated. The return line is returned for 2 minutes and the oil pressure is kept within the range of 0.7-1.5 kg/cm 2 .

16.2.3.2 Start the hydraulic oil pump, operate the reversing valve of the lock cylinder, and lock the adjusting ring.

16.2.3.3 Motor start and stop shall be carried out in accordance with the “motor operating procedures”.

16.2.3.4 After the motor is started, attention should be paid to the operation sound of the equipment and the position indicated by the ammeter. If there is an abnormality, stop the vehicle immediately and check it after normal operation.

16.2.3.5 After confirming that the various parts of the machine are in normal operation, start the mining belt, then open the dust water switch and start the ore belt.

16.2.4 When checking the power supply equipment, the power switch should be cut off first. It is strictly forbidden to carry live work. It is strictly forbidden to operate the electrical equipment with wet hands.

16.2.5 During work, it is not allowed to leave the job without authorization. The equipment may not be handed over to others for supervision without the approval of the relevant leaders.

16.2.6 The fuel tank cap and bearing cap must be sealed. It is strictly forbidden to enter dust and debris. The lubricating oil must be cooled and filtered. The cooling water pressure is lower than the oil pressure of 0.25-0.5 kg/cm 2 .

16.3 Maintenance and key inspection contents in operation:

16.3.1 The running check is carried out according to the following table, and the operation record is filled in in detail.

Check parts

Check content

Lubrication system

1. Does the machine pipe and oil pump have oil leakage?

2. Frequent inspection during operation, oil pressure, oil quantity and lubrication of individual bearings

3. Always check the circulation of lubricating oil. The general oil quantity should be maintained at 1/3 to 1/2 of the return pipe.

Various parts of the body

1. Screw tightening of each part

2. Adjust the ring fixing device for looseness

3. Check the base, upper shell and spring runout

4. Check if the tablet is loose

5. Pay attention to whether the transmission gear sound and vibration are normal.

6. Whether the ore is even or biased to one side, and whether the ore discharge size meets the requirements

Dustproof system

Check the water flow of the dust water

Electrical system

Check the motor temperature rise (≤60 °C) current, odor, vibration, etc. and the operation of the electronic control system

16.3.2 During the operation, the mobile guard device is not allowed to move, and if it is moved, it must be restored to its original state before it can be operated.

16.3.3 During operation, the running parts and electrical circuits cannot be touched by hand or body.

16.3.4 During the operation, the oil return temperature should not exceed 60 °C. If it exceeds the time, the measures should be taken to reduce the amount of ore, stop the cooling or change the oil.

16.4 Operation sequence and precautions for parking:

16.4.1 The sequence of parking operations is as follows:

16.4.1.1 Stop feeding.

16.4.1.2 Press the stop button or turn off the power switch.

16.4.1.3 Move the motor short-circuit ring to the parking position.

16.4.1.4 Stop the lubricating oil pump and hydraulic pump.

16.4.2 When there is no notice of power outage, the following measures shall be taken:

16.4.2.1 In the order of parking.

16.4.2.2 Remove all ore from the crushing chamber.

16.4.2.3 When it is necessary to stop the vehicle for maintenance due to failure, it shall be carried out in accordance with the provisions of Article 20, and then notify the relevant personnel not to handle it without authorization, and fill in the operation record in detail.

16.5 Possible causes of failure and methods of elimination:

Fault phenomenon

cause of issue

Elimination method

Crusher springs often

Being fatigued or sometimes broken

Spring screw broken

1. Unbalanced or excessive ore

2. Too many pieces in the ore

3. The discharge port is blocked by wet or sticky ore very small

4. Too much iron loss

5. The spring pressure is not enough

6. The spring strength is not enough

1. Adjusting the mine

2. Strengthen screening

3. Strengthening washing equipment

4. Strengthen iron selection measures

5. Press the spring but not exceed the specified maximum compression

6. Adjust according to actual conditions

With the fierce sound, the upper part is lifted up and then turned into normal

Falling into the broken cavity into the iron block or other non-broken objects

Strengthening iron selection equipment and hand selection measures

Gear overshoot

1. Gear meshing is improper

2. Bearing clearance is too large

3. Gear wear is too high

4. Lost teeth

5. The gear keys are loose

6. Gear machining error is too large

1. Adjust the gap

2. Adjust or replace

3. Replace

4. Repair or replacement

5. Reinforcement and key change

6. Repair or replacement

Strong noise during crushing

1. Broken wall loose

2. The rolling wall is loose

3. The bolt or hook on the fixed cone is broken

1. watered regularly checked again when the degree of filling and compression nut fastening zinc alloy where necessary fastening

2. Tighten the nut on the pressure plate to re-water the zinc alloy when it is loose.

3. Stop and remove the adjustment ring to replace it.

Noise when idling

The broken wall or the rolled wall is not rounded to produce impact or friction

Re-adjust gap or machining

Suddenly the two walls touched each other during the rotation

1. The two walls are loose

2. Vertical axis break

3. Spherical bearing damage

4. Hard iron block is stuck between the two walls

1. Fasten or refill zinc

2. Replacement

3. Replace

4. Take out

Hoarse sound, motor

Rotating the broken cone rotates too fast

1. Large gear or pinion damage

2. Vertical axis break

3. Gear roll button

4. The drive shaft is broken

Replace

2. Replacement

3. Change key

4. Replace

Crusher strong vibration

The broken cone rotates too fast

The vertical axis is stuck for several reasons

1. Lack of lubricating oil or oil is too dirty

2. The moving cone is broken or the spherical bearing is damaged.

3. The gap in the tapered bushing is not enough

Downtime to identify the cause to be eliminated

Broken shaft or gear teeth

Serious iron loss

2. Two walls meet

3. Hold the shaft

4. The amount of spring compression is too large

5. Conical bushing is not tapered

6. Poor gear processing quality

7. The vertical axis is in contact with the bottom tray

8. The crusher frequently moves

1. Strengthen iron removal facilities

2. Adjust the gap

3. Strengthen lubrication

4. Adjustment

5. Replacement

6. Replacement

7. Increase the gap

8. Take measures to eliminate

Oil temperature is too high

1. Poor oil quality or insufficient oil supply

2. Bearing damage

Replace or replenish

2. Replacement

In the indicator after starting the oil pump

No oil flow or low oil pressure

1. Oil is too cold

2. The valve is too tight

3. The oil pump is faulty

4. Oil line blockage or export oil leak

Heating

2. Open big

3. Overhaul or replace

4. Overhaul

Filter before and after oil pressure

The difference is too large

Filter blocked

Cleaning

Oil pressure rises oil temperature rises

Oil pipe or some parts are greased

Downtime cleaning

Oil temperature rises above 60 °C

But the oil pressure in the system does not increase

Eccentric shaft friction parts are faulty

Downtime maintenance

Significant reduction in oil return

1. The bottom cover flange of the machine leaks oil

2. The drive shaft housing bearing cover is not strict

3. The oil groove in the spherical bearing oil-blocking ring is blocked or the oil is leaked when the oil is too much.

4. Pipe joints are not strict

5. The horizontal axis is not tightly sealed.

6. Oil pressure is too high

7. Spherical bearing contact failure

Sealing treatment

2. Sealing treatment

3. Shutdown maintenance

4. Overhaul

5. Adjust or replace

6. Adjustment

7. Scraping or replacing

Flowing from the cooler

Oil temperature exceeds 45 ° C

1. Lack of cooling water

2. Cooling water temperature is high

3. Cooler blockage

Water supply

2. Adjust the water pressure

3. Cleaning

Water mixed into the oil

Water pressure is higher than oil pressure

Adjustment

Eccentric shaft rises, disc

Pins may be eccentric shaft slots

Fall out

1. The oil pump safety valve fails to make the oil pressure too high

2. The oil pump discharges a large amount of oil, and the oil barrier ring is blocked by the oil drain groove.

1. Adjust or replace

2. Inspection and cleaning

Dust-proof water mixed with a lot of oil

Oil temperature has not risen

Oil drain groove blocking

Cleaning

Water does not enter the water seal

Water pipe blockage or large leak

Downtime check eliminate

High current

Too much ore

2. Poor lubrication

3. Bearing damage

4. Spherical bearing damage

5. Bad bearing contact surface

6. The upper part of the large bevel gear and the lower part of the spherical bearing are rubbed

7. Vertical axis break

8. Fall into the iron block

9. Two walls meet

Adjustment

2. Strengthen lubrication

3. Replace

4. Replace

5. Re-scraping or replacing

6. Pad adjustment

7. Replacement

8. Strengthening iron selection measures

9. Adjustment